نوع مقاله : مقاله پژوهشی
عنوان مقاله English
نویسندگان English
Field-Oriented Control Strategy (FOCS) is normally utilized for motor drive systems to control the machine speed. One of the drawbacks of the conventional FOCS is its low-fault capability. This demerit is significant in many industries such as electric vehicles. This paper introduces a simple FOCS for Three-phase Induction Motors (TIMs) under an Open-phase Failure (OF). Based on the presented analysis in this paper, the proposed FOCS uses the Traditional Transformation (TT) for current and voltage components like the conventional FOCS. However, it has two more current PI controllers compared to the conventional FOCS. These two extra controllers are considered to compensate backward voltages. This method will improve the reliability of the entire drive system during an OF. Different simulations and experiments are conducted on a wye-connected TIM to verify the approach proposed in this paper. Results illustrate the capability of the suggested FOCS to reduce the torque ripple during the OF.
کلیدواژهها English